Project Description

Hot Sale Water/Fuel Tank Magnetic Level Gauge

UZ series magnetic float level gauge can safely and reliably measure liquid level under high temperature, high pressure, high viscosity and strong corrosion conditions, visual reading, eye-catching display, wide measurement range. Equipped with magnetic switch and liquid level remote transmitter, it can realize upper and lower limit alarm and control of liquid level (interface) and remote detection and control. This series of products are widely used in liquid level measurement and control in industrial processes of electric power, petroleum, chemical, pharmaceutical, metallurgy, environmental protection, construction, food and other industries. It can visually display the liquid level of medium in various towers, tanks, spherical containers and boiler equipment.

Technical Characteristics

  • It integrates on-site display, remote transmission and alarm switch with complete functions.

  • The liquid level display is completely isolated from the measuring medium, so the sealing performance is good, safe and reliable.

  • Various forms of installation, suitable for various occasions.

  • The wetted parts are made of different materials, which can measure corrosive, flammable, toxic, agitated and polluted liquids, and can be used in high temperature and high pressure environments.

Installation and Application Notes

  • The level gauge shall not be installed in a place where there is vigorous vibration.

  • The level gauge should be installed firmly. The measuring body must be installed vertically to the ground.

  • The gauge s around can not near the magnetic field, and the medium can not has magnetic impurity.

  • The gauge mount where the liquid waving is small.

  • The magnetic float should be taken out, when the pressure test being done and then remounted after the test being over.

  • When remounting the float notice the end with magnetism must be up or make the big float weight end upside.

  • When the magnetic level gauge running notice to open the top valve of level gauge first and then open the bottom valve slowly so as to avoid the pressed fluid flow into the body over rapidly and damage the magnetic float.

  • If the magnetic flakes inside of the indicator can not roll over normally proofread and correct it with the magnet steel or magnetic float over again.

  • According to the medium the inner of the main pipe should be rinsed timely so as to eliminate the deposit and purity.

Technical Parameters

【Host】
Measurement range: 5 ~ 2000mg / L, exceeding the dilution test. Indication error: ≤ ± 5 %
Repeatability: ≤3% Anti-chlorine interference: ≤2000mg/L
Optical system: 420nm (low range) and 610nm (medium and high range) Temperature control system: Can be set at room temperature ~200 °C, COD digestion temperature is 165 °C.
Temperature control accuracy: ±1 °C Temperature control time: Adjustable from 1 to 999 minutes
Resolution time: 15 min. Optical stability: Instrument absorbance drifts less than 0.002A in 20min
Batch volume: 4 water samples (or 16 water samples) Dimensions:  COD measuring instrument 80mm × 230mm × 55mm Digestion instrument 105mm × 160mm × 90mm
Weight: Host 0.5kg digestion instrument: 1kg Power supply: Rechargeable lithium battery